International Journal of Medical and Pharmaceutical Research
2023, Volume-4, Issue-3 doi: 10.5281/zenodo.7948564
Original Article
A Comparison of Urine Dipstick Test with Spot Urine Protein-Creatinine Ratio and 24 Hour Urine Protein Excretion in Women with Hypertensive Disorders of Pregnancy
 ,
 ,
 ,
Published
May 18, 2023
Abstract
Background: Estimation of 24hour urine protein excretion and evaluation of spot protein- creatinine ratio in a random urine sample have been standard methods for determination of protein excretion. . The urine dipstick method, a semi-quantitative method of proteinuria estimation, has long been used as a screening tool for the same purpose. The objective of this study was to assess the efficacy of dipstick as a test for measurement of proteinuria in comparison with 24 hour urinary protein collection and spot urine protein/creatinine ratio as a screening test in pregnant patients with suspected hypertensive disorder of pregnancy attending an obstetric outpatient service. Methods: 150 patients were recruited with suspected hypertensive disorders of pregnancy attending the obstetric outpatient service at our Department of Obstetrics and Gynecology and measured proteinuria in them by dipstick method, 24-hour urine protein collection and spot urine protein/creatinine ratio and calculated the degree of correlation between the first with the other two standard tests. Results: The correlation of the urine dipstick test values with the 24-hour urine protein excretion was strong (r=0.757),but when compared to the spot urine protein-creatinine ratio, it was moderate (r=0.612). At 1+ grading of proteinuria, urine dipstick demonstrated greater sensitivity but at 2+ grading, dipstick was more specific in identification of significant proteinuria. Conclusion: We conclude that dipstick as a test correlates better with 24 hour urine protein estimation than with the protein-creatinine ratio. Further, 1+ grading of urine dipstick could be a good screening tool for identifying proteinuria in patients attending the obstetrics outpatient service. However, the 2 + grading of the urine dipstick would be required to serve as an alternative to the 24-hour urine collection for detection of significant proteinuria or calculation of spot urine P/C ratio.
Recommended Articles
Loading Image...
Volume-4, Issue-3
Citations
2159 Views
416 Downloads
Share this article
License
Copyright (c) International Journal of Medical and Pharmaceutical Research
pdf Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.
All papers should be submitted electronically. All submitted manuscripts must be original work that is not under submission at another journal or under consideration for publication in another form, such as a monograph or chapter of a book. Authors of submitted papers are obligated not to submit their paper for publication elsewhere until an editorial decision is rendered on their submission. Further, authors of accepted papers are prohibited from publishing the results in other publications that appear before the paper is published in the Journal unless they receive approval for doing so from the Editor-In-Chief.
IJMPR open access articles are licensed under a Creative Commons Attribution-ShareAlike 4.0 International License. This license lets the audience to give appropriate credit, provide a link to the license, and indicate if changes were made and if they remix, transform, or build upon the material, they must distribute contributions under the same license as the original.
Logo
International Journal of Medical and Pharmaceutical Research
About Us
The International Journal of Medical and Pharmaceutical Research (IJMPR) is an EMBASE (Elsevier)–indexed, open-access journal for high-quality medical, pharmaceutical, and clinical research.
Follow Us
© Copyright IJMPR | All Rights Reserved